loading spinner
  • Ups Cyberpower 3000Va/2700W Rackmount 2U Online

Ups Cyberpower 3000Va/2700W Rackmount 2U Online

Referência: OL3000ERTXL2U

Ups Cyberpower 3000Va/2700W Rackmount 2U Online
Marca
Capacidade
Tipo aparelho
Descarregar PDF

Seguir o preço








































































































































































































































































































































General
UPS Topology Double-Conversion
Energy Saving ECO Mode Efficiency >93%
ENERGY STAR® Qualified Yes
Input
Voltage 100Vac - 125Vac
Input Voltage Range 60Vac - 69Vac for 0-60% Load, 70Vac - 79Vac for 0-70% Load, 80Vac - 89Vac for 0-80% Load, 90Vac - 95Vac for 0-90% Load, 96Vac - 150Vac for 0-100% Load
Input Frequency Range 40Hz – 70Hz (auto-sensing)
Input Power Factor 0.99
Cold Start Yes
Plug Type NEMA L5-30P
Cord Length 10'
Output
VA 3,000
Watts 2,700
On Battery Voltage 100, 110, 115, 120, 125Vac (Configurable) ± 2%
On Battery Frequency 50/60Hz (Auto-Sensing or Configurable) ±0.25Hz
On Battery Waveform Sine Wave
Outlets - Total 7
Outlet Type NEMA 5-20R (6) , L5-30R (1)
Rated Power Factor 0.9
Crest Factor 3:1
Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load
ECO Mode Voltage Regulation ±10%, ±15% (Configurable)
Overload Protection Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec, Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec
Bypass Internal Bypass (Automatic and Manual)
Transfer Time 0ms
Battery
Runtime at Half Load (min) 11
Runtime at Full Load (min) 3.5
Battery Type Sealed Lead-Acid
Battery Size 12V/9AH
Hot-Swappable Yes
Replacement Battery RB1290X6
Battery Quantity 6
User Replaceable Yes
Typical Recharge Time 4 Hours
Extended Battery Module BP72V60ART2U
Smart Battery Management (SBM) Mode Yes
Surge Protection & Filtering
Surge Suppression 1,335 Joules – IEC 61000-4-5 Level 3
Phone / Network Protection RJ11/RJ45 1-In / 1-Out
EMI/RFI Filtration Yes
Management & Communications
LCD Control Panel 43 different settings or status options via the UPS Status menu , UPS Setup menu, and run Testing menus. Refer to the "User Manual" on the "Resources" tab for complete options.
Rotatable LCD Control Panel No
Extendable LCD Control Panel Yes - Requires a separate DB26 Cable
HID Compliant USB Port Yes
Serial Port Yes
EPO Port Yes
Dry Contacts Yes
Management Cable USB Cable, Serial Cable
LED Indicators Power On (White), On-Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red)
Audible Alarms Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery
Software PowerPanel® Business Edition
SNMP / HTTP Remote Monitoring Yes, with optional RMCARD302, Yes, with optional RMCARD303
Physical
Rack Size 2U
Form Factor Rack/Tower
Mounting Hardware Included
Enclosure Construction Steel
Dimensions (WxHxD) (in.) 17 x 3.5 x 23.62
Dimensions (WxHxD) (mm.) 433 x 88 x 600
Weight (lbs.) 68.2
Weight (kg.) 31
Shipping Dimensions (WxHxD) (in.) 23.23 x 8.43 x 35.04
Shipping Dimensions (WxHxD) (mm.) 590 x 214.1 x 890
Shipping Weight (lbs.) 86.9
Shipping Weight (kg.) 39.4
Environmental
Operating Temperature -20°C – 45°C (-4°F - 113°F) at full power Operation at 50°C (122°F) with derating to 24W
Operating Humidity 0% - 90% non-condensing
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5°F to 113°F / -15°C to 45 °C
Storage Relative Humidity 0% - 95% non-condensing
Storage Elevation 0-50000 feet (0-15000 meters)
Online Thermal Dissipation 1,257 BTU/hr
Audible noise at 1.5M from surface of unit <50 dBA
Certifications
Safety UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Environmental RoHS Compliant